Eland Cables Cable Information (1)

N2XSEY Cable

to N2XSEY Cable datasheets

Key Features: N2XSEY Cable

  • Application: Three-core Medium voltage PVC power cables.
  • Suitability: For distribution networks and the connection to generation units and plant and process equipment. To be laid directly in ground, outdoors, indoors and in cable ducts.
  • Standards & Voltage Ratings: IEC 60502-2 and HD 620 10C. 6/10kV, 8.7/15kV, 12/20kV and 18/30kV.
  • Construction: Class 2 stranded Copper conductor, semi-conductive conductor screen, Cross-linked Polyethylene (XLPE) insulation, semi-conductive insulation screen, Copper wires and tape screen, and Polyvinyl Chloride (PVC) outer sheath.
  • Details: Single core variant (N2XSY) available. Flame retardant and self-extinguishing. UV resistant.

Eland Cables is a leading global supplier of power, instrumentation and data cables for critical infrastructure and electrification. Our complete cable solutions are underpinned by technical expertise and our Cable Lab®, ensures rigorous compliance. Contact our team to discuss your requirements.

N2XSEY cables are three-core class 2 stranded copper medium voltage cables manufactured in accordance with IEC 60502-2 and HD 620 10C.

They are the three-core variants of the cable N2XSY where the 'E' in the designation refers to each of the three cores being individually screened.

N2XSEY cables are widely used in the building and construction, renewable energy, and power transmission industries where the cables can be laid directly into the ground or cable ducts.

Being flame retardant and self-extinguishing, these Medium Voltage cables are compliant with the standard IEC 60332-1.

N2XSEY have Class 2 copper conductors covered with cross-linked polyethylene (XLPE) insulation. Each individual core has a copper wire screen, and then the three cores are covered with a polyvinyl chloride (PVC) oversheath.

As with all MV cables, there is an inner and outer layer of semi-conductive material to smooth out the internal discharges and maintain operational reliability.

These cables use German nomenclature, as explained in the table below.

N Energy Cable to Standard (default Copper conductor)
2X XLPE insulation
S Metallic screen
E Individually screened cores (three-core variant)
Y Polyvinyl Chloride 

N2XSEY cables are available in voltages including: 6/10kV, 8.7/15kV, 12/20kV and 18/30kV. The technical datasheets for each are available below. These voltages support most medium voltage infrastructure and equipment requirements.

Where additional technical support or electrical characteristics data is required, please speak to a member of the team who will be able to assist. 

FastQuote Logo

Your tailored quote direct to your inbox

Your basket is currently empty

Go back

More information

Construction Table

  N2XSEY Cable CS N2XSEY 6/10kV Cable
CONDUCTOR

Class 2 stranded Copper

INSULATION

XLPE (Cross-linked Polyethylene)

SCREEN

Copper wires and equalising tape

OUTER SHEATH

PVC (Polyvinyl Chloride)

YOUR CABLE OPTIONS

Use the FastQuote filters to find the exact cable specifications you need.

Need a bespoke solution? Learn more about customised cables.

Reset

Product name Part No Cores Nominal cross-sectional area (mm²) Sheath colour Length (m)  
N2XSEY 6/10kV CableA9X10KV3050350Red
N2XSEY 6/10kV CableA9X10KV3070370Red
N2XSEY 6/10kV CableA9X10KV3095395Red
N2XSEY 6/10kV CableA9X10KV31203120Red
N2XSEY 6/10kV CableA9X10KV31503150Red
N2XSEY 6/10kV CableA9X10KV31853185Red
N2XSEY 6/10kV CableA9X10KV32403240Red
N2XSEY 6/10kV CableA9X10KV33003300Red
N2XSEY 6/10kV CableA9X10KV34003400Red
N2XSEY 6/10kV CableA9X10KV35003500Red
N2XSEY 8.7/15kV CableA9X15KV3050350Red
N2XSEY 8.7/15kV CableA9X15KV3070370Red
N2XSEY 8.7/15kV CableA9X15KV3095395Red
N2XSEY 8.7/15kV CableA9X15KV31203120Red
N2XSEY 8.7/15kV CableA9X15KV31503150Red
N2XSEY 8.7/15kV CableA9X15KV31853185Red
N2XSEY 8.7/15kV CableA9X15KV32403240Red
N2XSEY 8.7/15kV CableA9X15KV33003300Red
N2XSEY 8.7/15kV CableA9X15KV34003400Red
N2XSEY 8.7/15kV CableA9X15KV35003500Red
N2XSEY 12/20kV CableA9X20KV3050350Red
N2XSEY 12/20kV CableA9X20KV3070370Red
N2XSEY 12/20kV CableA9X20KV3095395Red
N2XSEY 12/20kV CableA9X20KV31203120Red
N2XSEY 12/20kV CableA9X20KV31503150Red
N2XSEY 12/20kV CableA9X20KV31853185Red
N2XSEY 12/20kV CableA9X20KV32403240Red
N2XSEY 12/20kV CableA9X20KV33003300Red
N2XSEY 12/20kV CableA9X20KV34003400Red
N2XSEY 12/20kV CableA9X20KV35003500Red
N2XSEY 18/30kV CableA9X30KV3050350Red
N2XSEY 18/30kV CableA9X30KV3070370Red
N2XSEY 18/30kV CableA9X30KV3095395Red
N2XSEY 18/30kV CableA9X30KV31203120Red
N2XSEY 18/30kV CableA9X30KV31503150Red
N2XSEY 18/30kV CableA9X30KV31853185Red
N2XSEY 18/30kV CableA9X30KV32403240Red
N2XSEY 18/30kV CableA9X30KV33003300Red
N2XSEY 18/30kV CableA9X30KV34003400Red
N2XSEY 18/30kV CableA9X30KV35003500Red