XHIOAV, XHIO1AV, LXHIOAV & LXHIO1AV Cables
With their double layer of either tape armour - steel tape for the multicore variants and aluminium tape for the single core sizes - the XHIOAV, XHIO1AV, LXHIOAV & LXHIO1AV are referenced by Portuguese cable designations. These Medium Voltage cables are available from 3.6/6kV through to 18/30kV (higher voltages on request), and are manufactured in accordance with international standard IEC 60502-2.
Breaking down the cable names to determine the construction, the cables prefixed 'X' have Copper conductors, whilst 'LX' are Aluminium; the 'IO' references a Copper Tape and Wire screen to aid EMC and limit proximate interference. 'A' indicates the tape armour, with the addition of a 1 (as in '1A') indicates a single core cable hence the ATA instead of STA. Finally, the 'V' at the end of the cable names refers to the PVC (Polyvinyl Chloride) outer sheathing, offering flame retardancy to IEC 60332-1-2 and UV resistance.
PVC as a sheathing material offers good resistance to many oils, chemicals and alkalines, and is robust enough to be well-suited to external installations, including direct burial applications. Where the installation environment is waterlogged, including where cable ducts are subject to flooding, either additional waterblocking constructional layers should be added or alternatively the PE sheathed variant XHIOAE should be considered. Where a more robust SWA armour is preferred for the application, the XHIORV & LXHIORV would be suited.
As with all Medium Voltage cables, our technical team are on hand to provide support with specification and with identifying compatible accessories, and our international team are available to provide Portuguese language support where required.
XHIOAV, XHIO1AV, LXHIOAV & LXHIO1AV Cables
YOUR CABLE OPTIONS
Use the FastQuote filters to find the exact cable specifications you need.
Need a bespoke solution? Learn more about customised cables.
Product name | Part No | Cores | Nominal cross-sectional area (mm²) | Voltage Rating | Sheath colour | Length (m) | |
---|---|---|---|---|---|---|---|
XHIOAV Cable | MP4610K03025 | 3 | 25 | 10kV | Black | ||
XHIOAV Cable | MP4606KV03025 | 3 | 25 | 6kV | Black | ||
XHIOAV Cable | MP4615K03025 | 3 | 25 | 15kV | Black | ||
XHIOAV Cable | MP4620K03035 | 3 | 35 | 20kV | Black | ||
XHIOAV Cable | MP4610K03035 | 3 | 35 | 10kV | Black | ||
XHIOAV Cable | MP4606K03035 | 3 | 35 | 6kV | Black | ||
XHIOAV Cable | MP4615K03035 | 3 | 35 | 15kV | Black | ||
XHIOAV Cable | MP4620K03050 | 3 | 50 | 20kV | Black | ||
XHIOAV Cable | MP4610K03050 | 3 | 50 | 10kV | Black | ||
XHIOAV Cable | MP4606K03050 | 3 | 50 | 6kV | Black | ||
XHIOAV Cable | MP4615K03050 | 3 | 50 | 15kV | Black | ||
XHIOAV Cable | MP4630K03050 | 3 | 50 | 30kV | Black | ||
XHIOAV Cable | MP4620K03070 | 3 | 70 | 20kV | Black | ||
XHIOAV Cable | MP4610K03070 | 3 | 70 | 10kV | Black | ||
XHIOAV Cable | MP4606K03070 | 3 | 70 | 6kV | Black | ||
XHIOAV Cable | MP4615K03070 | 3 | 70 | 15kV | Black | ||
XHIOAV Cable | MP4630K03070 | 3 | 70 | 30kV | Black | ||
XHIOAV Cable | MP4620K03095 | 3 | 95 | 20kV | Black | ||
XHIOAV Cable | MP4610K03095 | 3 | 95 | 10kV | Black | ||
XHIOAV Cable | MP4606K03095 | 3 | 95 | 6kV | Black | ||
XHIOAV Cable | MP4615K03095 | 3 | 95 | 15kV | Black | ||
XHIOAV Cable | MP4630K03095 | 3 | 95 | 30kV | Black | ||
XHIOAV Cable | MP4620K03120 | 3 | 120 | 20kV | Black | ||
XHIOAV Cable | MP4610K03120 | 3 | 120 | 10kV | Black | ||
XHIOAV Cable | MP4606K03120 | 3 | 120 | 6kV | Black | ||
XHIOAV Cable | MP4615K03120 | 3 | 120 | 15kV | Black | ||
XHIOAV Cable | MP4630K03120 | 3 | 120 | 30kV | Black | ||
XHIOAV Cable | MP4620K03150 | 3 | 150 | 20kV | Black | ||
XHIOAV Cable | MP4610K03150 | 3 | 150 | 10kV | Black | ||
XHIOAV Cable | MP4606K03150 | 3 | 150 | 6kV | Black | ||
XHIOAV Cable | MP4615K03150 | 3 | 150 | 15kV | Black | ||
XHIOAV Cable | MP4630K03150 | 3 | 150 | 30kV | Black | ||
XHIOAV Cable | MP4620K03185 | 3 | 185 | 20kV | Black | ||
XHIOAV Cable | MP4610K03185 | 3 | 185 | 10kV | Black | ||
XHIOAV Cable | MP4606K03185 | 3 | 185 | 6kV | Black | ||
XHIOAV Cable | MP4615K03185 | 3 | 185 | 15kV | Black | ||
XHIOAV Cable | MP4630K03185 | 3 | 185 | 30kV | Black | ||
XHIOAV Cable | MP4620K03240 | 3 | 240 | 20kV | Black | ||
XHIOAV Cable | MP4610K03240 | 3 | 240 | 10kV | Black | ||
XHIOAV Cable | MP4606K03240 | 3 | 240 | 6kV | Black | ||
XHIOAV Cable | MP4615K03240 | 3 | 240 | 15kV | Black | ||
XHIOAV Cable | MP4630K03240 | 3 | 240 | 30kV | Black | ||
XHIOAV Cable | MP4620K03300 | 3 | 300 | 20kV | Black | ||
XHIOAV Cable | MP4610K03300 | 3 | 300 | 10kV | Black | ||
XHIOAV Cable | MP4606K03300 | 3 | 300 | 6kV | Black | ||
XHIOAV Cable | MP4615K03300 | 3 | 300 | 15kV | Black | ||
XHIOAV Cable | MP4630K03300 | 3 | 300 | 30kV | Black | ||
XHIOAV Cable | MP4620K03400 | 3 | 400 | 20kV | Black | ||
XHIOAV Cable | MP4610K03400 | 3 | 400 | 10kV | Black | ||
XHIOAV Cable | MP4606K03400 | 3 | 400 | 6kV | Black | ||
XHIOAV Cable | MP4615K03400 | 3 | 400 | 15kV | Black | ||
XHIOAV Cable | MP4630K03400 | 3 | 400 | 30kV | Black | ||
LXHIOAV Cable | MP5010K03025 | 3 | 25 | 10kV | Black | ||
LXHIOAV Cable | MP5015K03025 | 3 | 25 | 15kV | Black | ||
LXHIOAV Cable | MP5006KV03025 | 3 | 25 | 6kV | Black | ||
LXHIOAV Cable | MP5010K03035 | 3 | 35 | 10kV | Black | ||
LXHIOAV Cable | MP5015K03035 | 3 | 35 | 15kV | Black | ||
LXHIOAV Cable | MP5006K03035 | 3 | 35 | 6kV | Black | ||
LXHIOAV Cable | MP5020K03035 | 3 | 35 | 20kV | Black | ||
LXHIOAV Cable | MP5010K03050 | 3 | 50 | 10kV | Black | ||
LXHIOAV Cable | MP5015K03050 | 3 | 50 | 15kV | Black | ||
LXHIOAV Cable | MP5006K03050 | 3 | 50 | 6kV | Black | ||
LXHIOAV Cable | MP5020K03050 | 3 | 50 | 20kV | Black | ||
LXHIOAV Cable | MP5030K03050 | 3 | 50 | 30kV | Black | ||
LXHIOAV Cable | MP5010K03070 | 3 | 70 | 10kV | Black | ||
LXHIOAV Cable | MP5015K03070 | 3 | 70 | 15kV | Black | ||
LXHIOAV Cable | MP5006K03070 | 3 | 70 | 6kV | Black | ||
LXHIOAV Cable | MP5020K03070 | 3 | 70 | 20kV | Black | ||
LXHIOAV Cable | MP5030K03070 | 3 | 70 | 30kV | Black | ||
LXHIOAV Cable | MP5010K03095 | 3 | 95 | 10kV | Black | ||
LXHIOAV Cable | MP5015K03095 | 3 | 95 | 15kV | Black | ||
LXHIOAV Cable | MP5006K03095 | 3 | 95 | 6kV | Black | ||
LXHIOAV Cable | MP5020K03095 | 3 | 95 | 20kV | Black | ||
LXHIOAV Cable | MP5030K03095 | 3 | 95 | 30kV | Black | ||
LXHIOAV Cable | MP5010K03120 | 3 | 120 | 10kV | Black | ||
LXHIOAV Cable | MP5015K03120 | 3 | 120 | 15kV | Black | ||
LXHIOAV Cable | MP5006K03120 | 3 | 120 | 6kV | Black | ||
LXHIOAV Cable | MP5020K03120 | 3 | 120 | 20kV | Black | ||
LXHIOAV Cable | MP5030K03120 | 3 | 120 | 30kV | Black | ||
LXHIOAV Cable | MP5010K03150 | 3 | 150 | 10kV | Black | ||
LXHIOAV Cable | MP5015K03150 | 3 | 150 | 15kV | Black | ||
LXHIOAV Cable | MP5006K03150 | 3 | 150 | 6kV | Black | ||
LXHIOAV Cable | MP5020K03150 | 3 | 150 | 20kV | Black | ||
LXHIOAV Cable | MP5030K03150 | 3 | 150 | 30kV | Black | ||
LXHIOAV Cable | MP5010K03185 | 3 | 185 | 10kV | Black | ||
LXHIOAV Cable | MP5015K03185 | 3 | 185 | 15kV | Black | ||
LXHIOAV Cable | MP5006K03185 | 3 | 185 | 6kV | Black | ||
LXHIOAV Cable | MP5020K03185 | 3 | 185 | 20kV | Black | ||
LXHIOAV Cable | MP5030K03185 | 3 | 185 | 30kV | Black | ||
LXHIOAV Cable | MP5010K03240 | 3 | 240 | 10kV | Black | ||
LXHIOAV Cable | MP5015K03240 | 3 | 240 | 15kV | Black | ||
LXHIOAV Cable | MP5006K03240 | 3 | 240 | 6kV | Black | ||
LXHIOAV Cable | MP5020K03240 | 3 | 240 | 20kV | Black | ||
LXHIOAV Cable | MP5030K03240 | 3 | 240 | 30kV | Black | ||
LXHIOAV Cable | MP5010K03300 | 3 | 300 | 10kV | Black | ||
LXHIOAV Cable | MP5015K03300 | 3 | 300 | 15kV | Black | ||
LXHIOAV Cable | MP5006K03300 | 3 | 300 | 6kV | Black | ||
LXHIOAV Cable | MP5020K03300 | 3 | 300 | 20kV | Black | ||
LXHIOAV Cable | MP5030K03300 | 3 | 300 | 30kV | Black | ||
LXHIOAV Cable | MP5010K03400 | 3 | 400 | 10kV | Black | ||
LXHIOAV Cable | MP5015K03400 | 3 | 400 | 15kV | Black | ||
LXHIOAV Cable | MP5006K03400 | 3 | 400 | 6kV | Black | ||
LXHIOAV Cable | MP5020K03400 | 3 | 400 | 20kV | Black | ||
LXHIOAV Cable | MP5030K03400 | 3 | 400 | 30kV | Black | ||
XHIO1AV Cable | MP1915K01025 | 1 | 25 | 15kV | Black | ||
XHIO1AV Cable | MP1910K01025 | 1 | 25 | 10kV | Black | ||
XHIO1AV Cable | MP1906KV01025 | 1 | 25 | 6kV | Black | ||
XHIO1AV Cable | MP1920K01035 | 1 | 35 | 20kV | Black | ||
XHIO1AV Cable | MP1915K01035 | 1 | 35 | 15kV | Black | ||
XHIO1AV Cable | MP1910K01035 | 1 | 35 | 10kV | Black | ||
XHIO1AV Cable | MP1906K01035 | 1 | 35 | 6kV | Black | ||
XHIO1AV Cable | MP1920K01050 | 1 | 50 | 20kV | Black | ||
XHIO1AV Cable | MP1915K01050 | 1 | 50 | 15kV | Black | ||
XHIO1AV Cable | MP1910K01050 | 1 | 50 | 10kV | Black | ||
XHIO1AV Cable | MP1906K01050 | 1 | 50 | 6kV | Black | ||
XHIO1AV Cable | MP1930K01050 | 1 | 50 | 30kV | Black | ||
XHIO1AV Cable | MP1920K01070 | 1 | 70 | 20kV | Black | ||
XHIO1AV Cable | MP1915K01070 | 1 | 70 | 15kV | Black | ||
XHIO1AV Cable | MP1910K01070 | 1 | 70 | 10kV | Black | ||
XHIO1AV Cable | MP1906K01070 | 1 | 70 | 6kV | Black | ||
XHIO1AV Cable | MP1930K01070 | 1 | 70 | 30kV | Black | ||
XHIO1AV Cable | MP1920K01095 | 1 | 95 | 20kV | Black | ||
XHIO1AV Cable | MP1915K01095 | 1 | 95 | 15kV | Black | ||
XHIO1AV Cable | MP1910K01095 | 1 | 95 | 10kV | Black | ||
XHIO1AV Cable | MP1906K01095 | 1 | 95 | 6kV | Black | ||
XHIO1AV Cable | MP1930K01095 | 1 | 95 | 30kV | Black | ||
XHIO1AV Cable | MP1920K01120 | 1 | 120 | 20kV | Black | ||
XHIO1AV Cable | MP1915K01120 | 1 | 120 | 15kV | Black | ||
XHIO1AV Cable | MP1910K01120 | 1 | 120 | 10kV | Black | ||
XHIO1AV Cable | MP1906K01120 | 1 | 120 | 6kV | Black | ||
XHIO1AV Cable | MP1930K01120 | 1 | 120 | 30kV | Black | ||
XHIO1AV Cable | MP1920K01150 | 1 | 150 | 20kV | Black | ||
XHIO1AV Cable | MP1915K01150 | 1 | 150 | 15kV | Black | ||
XHIO1AV Cable | MP1910K01150 | 1 | 150 | 10kV | Black | ||
XHIO1AV Cable | MP1906K01150 | 1 | 150 | 6kV | Black | ||
XHIO1AV Cable | MP1930K01150 | 1 | 150 | 30kV | Black | ||
XHIO1AV Cable | MP1920K01185 | 1 | 185 | 20kV | Black | ||
XHIO1AV Cable | MP1915K01185 | 1 | 185 | 15kV | Black | ||
XHIO1AV Cable | MP1910K01185 | 1 | 185 | 10kV | Black | ||
XHIO1AV Cable | MP1906K01185 | 1 | 185 | 6kV | Black | ||
XHIO1AV Cable | MP1930K01185 | 1 | 185 | 30kV | Black | ||
XHIO1AV Cable | MP1920K01240 | 1 | 240 | 20kV | Black | ||
XHIO1AV Cable | MP1915K01240 | 1 | 240 | 15kV | Black | ||
XHIO1AV Cable | MP1910K01240 | 1 | 240 | 10kV | Black | ||
XHIO1AV Cable | MP1906K01240 | 1 | 240 | 6kV | Black | ||
XHIO1AV Cable | MP1930K01240 | 1 | 240 | 30kV | Black | ||
XHIO1AV Cable | MP1920K01300 | 1 | 300 | 20kV | Black | ||
XHIO1AV Cable | MP1915K01300 | 1 | 300 | 15kV | Black | ||
XHIO1AV Cable | MP1910K01300 | 1 | 300 | 10kV | Black | ||
XHIO1AV Cable | MP1906K01300 | 1 | 300 | 6kV | Black | ||
XHIO1AV Cable | MP1930K01300 | 1 | 300 | 30kV | Black | ||
XHIO1AV Cable | MP1920K01400 | 1 | 400 | 20kV | Black | ||
XHIO1AV Cable | MP1915K01400 | 1 | 400 | 15kV | Black | ||
XHIO1AV Cable | MP1910K01400 | 1 | 400 | 10kV | Black | ||
XHIO1AV Cable | MP1906K01400 | 1 | 400 | 6kV | Black | ||
XHIO1AV Cable | MP1930K01400 | 1 | 400 | 30kV | Black | ||
XHIO1AV Cable | MP1920K01500 | 1 | 500 | 20kV | Black | ||
XHIO1AV Cable | MP1915K01500 | 1 | 500 | 15kV | Black | ||
XHIO1AV Cable | MP1910K01500 | 1 | 500 | 10kV | Black | ||
XHIO1AV Cable | MP1906K01500 | 1 | 500 | 6kV | Black | ||
XHIO1AV Cable | MP1930K01500 | 1 | 500 | 30kV | Black | ||
XHIO1AV Cable | MP1920K01630 | 1 | 630 | 20kV | Black | ||
XHIO1AV Cable | MP1915K01630 | 1 | 630 | 15kV | Black | ||
XHIO1AV Cable | MP1910K01630 | 1 | 630 | 10kV | Black | ||
XHIO1AV Cable | MP1906K01630 | 1 | 630 | 6kV | Black | ||
XHIO1AV Cable | MP1930K01630 | 1 | 630 | 30kV | Black | ||
LXHIO1AV Cable | MP2315K01025 | 1 | 25 | 15kV | Black | ||
LXHIO1AV Cable | MP2306KV01025 | 1 | 25 | 6kV | Black | ||
LXHIO1AV Cable | MP2310K01025 | 1 | 25 | 10kV | Black | ||
LXHIO1AV Cable | MP2320K01035 | 1 | 35 | 20kV | Black | ||
LXHIO1AV Cable | MP2315K01035 | 1 | 35 | 15kV | Black | ||
LXHIO1AV Cable | MP2306K01035 | 1 | 35 | 6kV | Black | ||
LXHIO1AV Cable | MP2310K01035 | 1 | 35 | 10kV | Black | ||
LXHIO1AV Cable | MP2320K01050 | 1 | 50 | 20kV | Black | ||
LXHIO1AV Cable | MP2315K01050 | 1 | 50 | 15kV | Black | ||
LXHIO1AV Cable | MP2306K01050 | 1 | 50 | 6kV | Black | ||
LXHIO1AV Cable | MP2330K01050 | 1 | 50 | 30kV | Black | ||
LXHIO1AV Cable | MP2310K01050 | 1 | 50 | 10kV | Black | ||
LXHIO1AV Cable | MP2320K01070 | 1 | 70 | 20kV | Black | ||
LXHIO1AV Cable | MP2315K01070 | 1 | 70 | 15kV | Black | ||
LXHIO1AV Cable | MP2306K01070 | 1 | 70 | 6kV | Black | ||
LXHIO1AV Cable | MP2330K01070 | 1 | 70 | 30kV | Black | ||
LXHIO1AV Cable | MP2310K01070 | 1 | 70 | 10kV | Black | ||
LXHIO1AV Cable | MP2320K01095 | 1 | 95 | 20kV | Black | ||
LXHIO1AV Cable | MP2315K01095 | 1 | 95 | 15kV | Black | ||
LXHIO1AV Cable | MP2306K01095 | 1 | 95 | 6kV | Black | ||
LXHIO1AV Cable | MP2330K01095 | 1 | 95 | 30kV | Black | ||
LXHIO1AV Cable | MP2310K01095 | 1 | 95 | 10kV | Black | ||
LXHIO1AV Cable | MP2320K01120 | 1 | 120 | 20kV | Black | ||
LXHIO1AV Cable | MP2315K01120 | 1 | 120 | 15kV | Black | ||
LXHIO1AV Cable | MP2306K01120 | 1 | 120 | 6kV | Black | ||
LXHIO1AV Cable | MP2330K01120 | 1 | 120 | 30kV | Black | ||
LXHIO1AV Cable | MP2310K01120 | 1 | 120 | 10kV | Black | ||
LXHIO1AV Cable | MP2320K01150 | 1 | 150 | 20kV | Black | ||
LXHIO1AV Cable | MP2315K01150 | 1 | 150 | 15kV | Black | ||
LXHIO1AV Cable | MP2306K01150 | 1 | 150 | 6kV | Black | ||
LXHIO1AV Cable | MP2330K01150 | 1 | 150 | 30kV | Black | ||
LXHIO1AV Cable | MP2310K01150 | 1 | 150 | 10kV | Black | ||
LXHIO1AV Cable | MP2320K01185 | 1 | 185 | 20kV | Black | ||
LXHIO1AV Cable | MP2315K01185 | 1 | 185 | 15kV | Black | ||
LXHIO1AV Cable | MP2306K01185 | 1 | 185 | 6kV | Black | ||
LXHIO1AV Cable | MP2330K01185 | 1 | 185 | 30kV | Black | ||
LXHIO1AV Cable | MP2310K01185 | 1 | 185 | 10kV | Black | ||
LXHIO1AV Cable | MP2320K01240 | 1 | 240 | 20kV | Black | ||
LXHIO1AV Cable | MP2315K01240 | 1 | 240 | 15kV | Black | ||
LXHIO1AV Cable | MP2306K01240 | 1 | 240 | 6kV | Black | ||
LXHIO1AV Cable | MP2330K01240 | 1 | 240 | 30kV | Black | ||
LXHIO1AV Cable | MP2310K01240 | 1 | 240 | 10kV | Black | ||
LXHIO1AV Cable | MP2320K01300 | 1 | 300 | 20kV | Black | ||
LXHIO1AV Cable | MP2315K01300 | 1 | 300 | 15kV | Black | ||
LXHIO1AV Cable | MP2306K01300 | 1 | 300 | 6kV | Black | ||
LXHIO1AV Cable | MP2330K01300 | 1 | 300 | 30kV | Black | ||
LXHIO1AV Cable | MP2310K01300 | 1 | 300 | 10kV | Black | ||
LXHIO1AV Cable | MP2320K01400 | 1 | 400 | 20kV | Black | ||
LXHIO1AV Cable | MP2315K01400 | 1 | 400 | 15kV | Black | ||
LXHIO1AV Cable | MP2306K01400 | 1 | 400 | 6kV | Black | ||
LXHIO1AV Cable | MP2330K01400 | 1 | 400 | 30kV | Black | ||
LXHIO1AV Cable | MP2310K01400 | 1 | 400 | 10kV | Black | ||
LXHIO1AV Cable | MP2320K01500 | 1 | 500 | 20kV | Black | ||
LXHIO1AV Cable | MP2315K01500 | 1 | 500 | 15kV | Black | ||
LXHIO1AV Cable | MP2306K01500 | 1 | 500 | 6kV | Black | ||
LXHIO1AV Cable | MP2330K01500 | 1 | 500 | 30kV | Black | ||
LXHIO1AV Cable | MP2310K01500 | 1 | 500 | 10kV | Black | ||
LXHIO1AV Cable | MP2320K01630 | 1 | 630 | 20kV | Black | ||
LXHIO1AV Cable | MP2315K01630 | 1 | 630 | 15kV | Black | ||
LXHIO1AV Cable | MP2306K01630 | 1 | 630 | 6kV | Black | ||
LXHIO1AV Cable | MP2330K01630 | 1 | 630 | 30kV | Black | ||
LXHIO1AV Cable | MP2310K01630 | 1 | 630 | 10kV | Black |