Eland Cables Cable Information (1)

Photovoltaic PV H1Z2Z2-K Cable

Our photovoltaic (PV) cables are intended for interconnecting power supplies within renewable energy photovoltaic systems such as solar panel arrays in solar energy farms. They are manufactured in accordance with European Standard EN 50618 and with the harmonised designation H1Z2Z2-K. This standard supersedes the previous TÜV approved PV1-F cable.

 

PV Solar Cable Specification

These Solar DC Cable are specified cables for use in Photovoltaic (PV) systems, and in particular those for installation at Direct Current (DC) side. They are suitable for fixed installations, both internal and external, and within conduits or systems. Their robust sheathing and impact testing means they are designated suitable for direct burial. EN 50618 requires cables to be low smoke zero halogen and be flexible tin-coated copper conductors with a single core and cross-linked insulation and sheath.

The compounds used in the insulation and outer sheathing are halogen free cross-linked, hence the reference to these cables as "cross-linked solar power cables". The EN50618 standard sheathing has a thicker wall than the PV1-F cable version. The cable sheathing is rated AD8 Water Resistant.

As with the TÜV PV1-F cable, the EN50618 cable benefits from a double-insulation offering increased safety. The Low Smoke Zero Halogen (LSZH) insulation and sheathing makes them suitable for use in environments where corrosive smoke would present a risk to human life in the event of fire.

H1Z2Z2-K Cable Voltage Rating

With a nominal DC voltage of up to 1.5kV between conductors, and not exceeding 1800V between conductor and earth, these cables are required to be tested at a voltage of 11kV AC 50Hz. They have an operating temperature range of -40oC to +90oC. 

FastQuote Logo

Your tailored quote direct to your inbox

Your basket is currently empty

Go back

More information

Solar Panel Installation - Solar Aluminium Cable and Accessories 

For full technical specifications please refer to the datasheet or speak to our technical team for more advice. Solar cable accessories are also available.

These PV cables are ozone-resistant according to BS EN 50396, UV-resistant according to HD605/A1, and tested for durability according to EN 60216. For a limited time, the TÜV approved PV1-F photovoltaic cable will still be available from stock.

A wider range of cables for renewables installations is also available including onshore and offshore wind turbines, hydroelectric and biomass production are also available.

Construction Table

  Photovoltaic Cable CS Photovoltaic PV H1Z2Z2-K Cable
VOLTAGE

AC: 0.6/1kV
DC: 900/1800V

CONDUCTOR

Class 5 Flexible Stranded Tinned Copper

INSULATION

Halogen-Free Cross-Linked Compound

OUTER SHEATH

Halogen-Free Cross-Linked, Flame Retardant Compound

Photovoltaic PV H1Z2Z2-K Cable

1 product(s)

YOUR CABLE OPTIONS

Use the FastQuote filters to find the exact cable specifications you need.

Need a bespoke solution? Learn more about customised cables.

Reset

Product name Part No Cores Nominal cross-sectional area (mm²) Sheath colour Length (m)  
Photovoltaic PV H1Z2Z2-K CableE6S10015BK11.5mm²Black
Photovoltaic PV H1Z2Z2-K CableE6S10025BK00012.5mm²Black
Photovoltaic PV H1Z2Z2-K CableE6S10040BK00014mm²Black
Photovoltaic PV H1Z2Z2-K CableE6S10060BK00016mm²Black
Photovoltaic PV H1Z2Z2-K CableE6S10100BK000110mm²Black
Photovoltaic PV H1Z2Z2-K CableE6S10160BK000116mm²Black
Photovoltaic PV H1Z2Z2-K CableE6S10250BK000125mm²Black
Photovoltaic PV H1Z2Z2-K CableE6S10350BK000135mm²Black
Photovoltaic PV H1Z2Z2-K CableE6S10500BK000150mm²Black
Photovoltaic PV H1Z2Z2-K CableE6S10700BK000170mm²Black
Photovoltaic PV H1Z2Z2-K CableE6S10950BK000195mm²Black
Photovoltaic PV H1Z2Z2-K CableE6S11200BK0001120mm²Black
Photovoltaic PV H1Z2Z2-K CableE6S11500BK0001150mm²Black
Photovoltaic PV H1Z2Z2-K CableE6S11850BK0001185mm²Black
Photovoltaic PV H1Z2Z2-K CableE6S12400BK0001240mm²Black