Key Features: NYFGY Cable
- Application: Medium Voltage armoured cable.
- Suitability: For power plants and heavy industrial settings requiring critical power connections.
- Standards & Voltage Rating: DIN VDE 0271. 3.6/6kV.
- Construction: Class 2 stranded Copper conductor, Polyvinyl Chloride (PVC) insulation and sheathing, and Steel Wire Armour (SWA).
- Details: Commonly specified in 3 core configuration, and in core sizes from 35mm2 to 240mm2. Flame retardant.
Eland Cables is a leading global supplier of power, instrumentation and data cables for critical infrastructure and electrification. Our complete cable solutions are underpinned by technical expertise and our Cable Lab®, ensures rigorous compliance. Contact our team to discuss your requirements.
NYFGY cables are Medium Voltage rigid armoured cables with flat steel wires, manufactured in accordance with German standard DIN VDE 0271.
Insulated and sheathed in PVC, the NYFGY cable is less commonly used than the BS6622 or BS7835 British standard armoured cables, yet is still specified for a range of applications, often where the connected equipment is temperature limited.
It has an operating temperature range of -5oC to +70oC owing to the PVC insulation layer. Cables such as the N2XSY MV range with XLPE insulation have a higher +90oC operating temperature.
Armour is not commonly required in European standard MV installations - unless specifically stated, direct burial cables do not have integral mechanical protection. As a result, the NYFGY cable is used where there is high risk of mechanical damage, such as power plants and heavy industrial settings where critical power must be maintained.
The NYFGY cable provided here has a voltage rating of 3.6/6kV. Our portfolio includes armoured cables to European and international standards across all voltages. Please speak to our MV specialists for support in specifying NYFGY cables or other appropriate cable.
The NYFGY is commonly specified in 3 core configuration, and in core sizes from 35mm2 to 240mm2, but other sizes can be requested directly.
More information
YOUR CABLE OPTIONS
Use the FastQuote filters to find the exact cable specifications you need.
Need a bespoke solution? Learn more about customised cables.
| Product name | Part No | Cores | Nominal cross-sectional area (mm²) | Sheath colour | Length (m) | |
|---|---|---|---|---|---|---|
| NYFGY 3.6/6kV Cable | B9N03035RD | 3 | 35mm² | Red | ||
| NYFGY 3.6/6kV Cable | B9N03050RD | 3 | 50mm² | Red | ||
| NYFGY 3.6/6kV Cable | B9N03070RD | 3 | 70mm² | Red | ||
| NYFGY 3.6/6kV Cable | B9N03095RD | 3 | 95mm² | Red | ||
| NYFGY 3.6/6kV Cable | B9N03120RD | 3 | 120mm² | Red | ||
| NYFGY 3.6/6kV Cable | B9N03150RD | 3 | 150mm² | Red | ||
| NYFGY 3.6/6kV Cable | B9N03185RD | 3 | 185mm² | Red | ||
| NYFGY 3.6/6kV Cable | B9N03240RD | 3 | 240mm² | Red |