(N)3GHSSYCY Cables
to (N)3GHSSYCY Cable datasheets
Key Features: (N)3GHSSYCY Cables
- Application: Medium voltage flexible energy supply cables.
- Suitability: Connection for tunnelling and underground mining equipment.
- Standards & Voltage Rating: VDE0250. 3.6/6kv, 6/10kV or 8.7/15kV, 12/20kV.
- Construction: Class 5 Flexible Stranded Copper phase conductor, Rubber Compound insulation, Semi-conductive layers, Individual Copper Wire Screen earth conductor, Class 5 tinned copper control conductor, Central filler, Polyvinyl Chloride (PVC) inner sheath, Copper Wire monitoring conductor, second PVC inner sheath, Steel Wire Braid (SWB) armour, and PVC outer sheath.
- Details: 3 phase + 3 earth + 3 control conductor configuration.
Our (N)3GHSSYCY is a flexible energy supply cable designed to supply power to medium voltage (MV) equipment. This range is manufactured in accordance with VDE0250 standard and it is designed to operate effectively in tunnelling and underground mining applications. This cable is designed with optimised insulation wall thickness and optimised outer diameter. It also allows effective monitoring of outer damage an invaluable property given the hazardous environments in which this cable tends to operate.
The (N)3GHSSYCY is available with a Voltage Rating of 3.6/6kv, 6/10kV or 8.7/15kV, 12/20kV. They operate in ambient temperatures of -40oC to +80oC when fixed and +5oC to +80oC when flexed.
Technical support for (N)3GHSSYCY and other mining cables
As a leading supplier of cables for the mining industry across infrastructure and mining applications, Eland Cables' technical team has a wealth of experience advising on opencast mining cable selection and applications for enclosed spaces. Please contact us to discuss your specific technical and logistical requirements.
More information
(N)3GHSSYCY Cables
YOUR CABLE OPTIONS
Use the FastQuote filters to find the exact cable specifications you need.
Need a bespoke solution? Learn more about customised cables.
| Product name | Part No | Cores | Nominal cross-sectional area (mm²) | Phase Conductor Size | Voltage Rating | Sheath colour | Length (m) | |
|---|---|---|---|---|---|---|---|---|
| (N)3GHSSYCY - 3.6/6kV and 6/10kV Cable | A7F06KV1025RD | 3+3+3+UL | 25mm² | 25 | 3.6/6kV | Red | ||
| (N)3GHSSYCY - 3.6/6kV and 6/10kV Cable | A7F06KV1035RD | 3+3+3+UL | 35mm² | 35 | 3.6/6kV | Red | ||
| (N)3GHSSYCY - 3.6/6kV and 6/10kV Cable | A7F06KV1050RD | 3+3+3+UL | 50mm² | 50 | 3.6/6kV | Red | ||
| (N)3GHSSYCY - 3.6/6kV and 6/10kV Cable | A7F06KV1070RD | 3+3+3+UL | 70mm² | 70 | 3.6/6kV | Red | ||
| (N)3GHSSYCY - 3.6/6kV and 6/10kV Cable | A7F06KV1095RD | 3+3+3+UL | 95mm² | 95 | 3.6/6kV | Red | ||
| (N)3GHSSYCY - 3.6/6kV and 6/10kV Cable | A7F06KV1120RD | 3+3+3+UL | 120mm² | 120 | 3.6/6kV | Red | ||
| (N)3GHSSYCY - 3.6/6kV and 6/10kV Cable | A7F06KV1150RD | 3+3+3+UL | 150mm² | 150 | 3.6/6kV | Red | ||
| (N)3GHSSYCY - 3.6/6kV and 6/10kV Cable | A7F10KV1025RD | 3+3+3+UL | 25mm² | 25 | 6/10kV | Red | ||
| (N)3GHSSYCY - 3.6/6kV and 6/10kV Cable | A7F10KV1035RD | 3+3+3+UL | 35mm² | 35 | 6/10kV | Red | ||
| (N)3GHSSYCY - 3.6/6kV and 6/10kV Cable | A7F10KV1050RD | 3+3+3+UL | 50mm² | 50 | 6/10kV | Red | ||
| (N)3GHSSYCY - 3.6/6kV and 6/10kV Cable | A7F10KV1070RD | 3+3+3+UL | 70mm² | 70 | 6/10kV | Red | ||
| (N)3GHSSYCY - 3.6/6kV and 6/10kV Cable | A7F10KV1095RD | 3+3+3+UL | 95mm² | 95 | 6/10kV | Red | ||
| (N)3GHSSYCY - 3.6/6kV and 6/10kV Cable | A7F10KV1120RD | 3+3+3+UL | 120mm² | 120 | 6/10kV | Red | ||
| (N)3GHSSYCY - 3.6/6kV and 6/10kV Cable | A7F10KV1150RD | 3+3+3+UL | 150mm² | 150 | 6/10kV | Red | ||
| (N)3GHSSYCY - 8.7/15kV and 12/20kV Cable | A7F15KV1025RD | 3+3+3+UL | 25mm² | 25 | 8.7/15kV | Red | ||
| (N)3GHSSYCY - 8.7/15kV and 12/20kV Cable | A7F15KV1035RD | 3+3+3+UL | 35mm² | 35 | 8.7/15kV | Red | ||
| (N)3GHSSYCY - 8.7/15kV and 12/20kV Cable | A7F15KV1050RD | 3+3+3+UL | 50mm² | 50 | 8.7/15kV | Red | ||
| (N)3GHSSYCY - 8.7/15kV and 12/20kV Cable | A7F15KV1070RD | 3+3+3+UL | 70mm² | 70 | 8.7/15kV | Red | ||
| (N)3GHSSYCY - 8.7/15kV and 12/20kV Cable | A7F15KV1095RD | 3+3+3+UL | 95mm² | 95 | 8.7/15kV | Red | ||
| (N)3GHSSYCY - 8.7/15kV and 12/20kV Cable | A7F15KV1120RD | 3+3+3+UL | 120mm² | 120 | 8.7/15kV | Red | ||
| (N)3GHSSYCY - 8.7/15kV and 12/20kV Cable | A7F20KV1025RD | 3+3+3+UL | 25mm² | 25 | 12/20kV | Red | ||
| (N)3GHSSYCY - 8.7/15kV and 12/20kV Cable | A7F20KV1035RD | 3+3+3+UL | 35mm² | 35 | 12/20kV | Red | ||
| (N)3GHSSYCY - 8.7/15kV and 12/20kV Cable | A7F20KV1050RD | 3+3+3+UL | 50mm² | 50 | 12/20kV | Red | ||
| (N)3GHSSYCY - 8.7/15kV and 12/20kV Cable | A7F20KV1070RD | 3+3+3+UL | 70mm² | 70 | 12/20kV | Red | ||
| (N)3GHSSYCY - 8.7/15kV and 12/20kV Cable | A7F20KV1095RD | 3+3+3+UL | 95mm² | 95 | 12/20kV | Red | ||
| (N)3GHSSYCY - 8.7/15kV and 12/20kV Cable | A7F20KV1120RD | 3+3+3+UL | 120mm² | 120 | 12/20kV | Red |