N2XCH Cables

N2XCH-J and N2XCH-O cables are fixed installation low voltage 1kV power cables used predominantly in the European market. Their flame retardant, non-corrosive (FRNC) low smoke zero halogen outer sheath makes them suitable for use in public buildings, in dry and damp environments, on or under plaster, laid on cable trays, in walls and in concrete. They are CPR compliant.

The N2XCH cable has copper wires and copper tape which act as a concentric conductor, laid on an inner sheath separating the insulated cores from the outer sheath. These additional layers and the copper wires and tape are not specifically designed to provide additional mechanical protection so the N2XCH should not be used in direct burial installation environments without further protection from mechanical stress and water ingress.

N2XCH-J and N2XCH-O Copper Conductor shapes

N2XCH cables with a conductor cross-sectional area size of more than 16mm2 the cores are sectorial shaped rather than circular. 

RE Class 1 solid - round
SE Class 1 solid - sectorial
RM Class 2 stranded - round
SM Class 2 stranded - sectorial

N2XCH cable selection

In addition to our portfolio of European power cables manufactured in accordance with IEC60502-1, including the N2XH cable, we also supply British standard low voltage power cables including armoured cable BS6724 cable with its LSZH outer sheathing which are suitable for direct burial applications. Our technical has a wealth of experience in providing support in the selection of the right cable for your application. Please call to discuss your specific application.

Fastquote En

Your tailored quote direct to your inbox

Your basket is currently empty

Go back

Construction Table

  n2xch-cable-end_1.png N2XCH IEC 60502-1 XLPE CWS FRNC 0.6/1kV Cable
VOLTAGE

0.6/1kV

CONDUCTOR

Up to 25mm2: Class 1 Solid Copper
Above 25mm2: Class 2 Copper

INSULATION

XLPE (Cross-Linked Polyethylene)

INNER SHEATH

Halogen-Free Compound

CONCENTRIC CONDUCTOR

Copper Wires with Counter Helix of Copper Tape

OUTER SHEATH

FRNC Compound (Flame Retardant Non-Corrosive)

YOUR CABLE OPTIONS

Use the FastQuote filters to find the exact cable specifications you need.

Need a bespoke solution? Learn more about customised cables.

Reset

Product name Part No Cores Nominal cross-sectional area (mm²) Type Sheath colour Length (m)  
N2XCH IEC 60502-1 XLPE CWS FRNC 0.6/1kV Cable A5N2XCH02015 2 1.5 RE Black
N2XCH IEC 60502-1 XLPE CWS FRNC 0.6/1kV Cable A5N2XCH02025 2 2.5 RE Black
N2XCH IEC 60502-1 XLPE CWS FRNC 0.6/1kV Cable A5N2XCH02040 2 4 RE Black
N2XCH IEC 60502-1 XLPE CWS FRNC 0.6/1kV Cable A5N2XCH02060 2 6 RE Black
N2XCH IEC 60502-1 XLPE CWS FRNC 0.6/1kV Cable A5N2XCH0210 2 10 RE Black
N2XCH IEC 60502-1 XLPE CWS FRNC 0.6/1kV Cable A5N2XCH0216 2 16 RE Black
N2XCH IEC 60502-1 XLPE CWS FRNC 0.6/1kV Cable A5N2XCH03015 3 1.5 RE Black
N2XCH IEC 60502-1 XLPE CWS FRNC 0.6/1kV Cable A5N2XCH03025 3 2.5 RE Black
N2XCH IEC 60502-1 XLPE CWS FRNC 0.6/1kV Cable A5N2XCH03040 3 4 RE Black
N2XCH IEC 60502-1 XLPE CWS FRNC 0.6/1kV Cable A5N2XCH03060 3 6 RE Black
N2XCH IEC 60502-1 XLPE CWS FRNC 0.6/1kV Cable A5N2XCH0310 3 10 RE Black
N2XCH IEC 60502-1 XLPE CWS FRNC 0.6/1kV Cable A5N2XCH0316 3 16 RE Black
N2XCH IEC 60502-1 XLPE CWS FRNC 0.6/1kV Cable A5N2XCH0325 3 25 RM Black
N2XCH IEC 60502-1 XLPE CWS FRNC 0.6/1kV Cable A5N2XCH0335 3 35 SM Black
N2XCH IEC 60502-1 XLPE CWS FRNC 0.6/1kV Cable A5N2XCH0350 3 50 SMv Black
N2XCH IEC 60502-1 XLPE CWS FRNC 0.6/1kV Cable A5N2XCH0370 3 70 SMv Black
N2XCH IEC 60502-1 XLPE CWS FRNC 0.6/1kV Cable A5N2XCH0395 3 95 SMv Black
N2XCH IEC 60502-1 XLPE CWS FRNC 0.6/1kV Cable A5N2XCH03120 3 120 SMv Black
N2XCH IEC 60502-1 XLPE CWS FRNC 0.6/1kV Cable A5N2XCH03150 3 150 SMv Black
N2XCH IEC 60502-1 XLPE CWS FRNC 0.6/1kV Cable A5N2XCH03185 3 185 SMv Black
N2XCH IEC 60502-1 XLPE CWS FRNC 0.6/1kV Cable A5N2XCH03240 3 240 SMv Black
N2XCH IEC 60502-1 XLPE CWS FRNC 0.6/1kV Cable A5N2XCH04015 4 1.5 RE Black
N2XCH IEC 60502-1 XLPE CWS FRNC 0.6/1kV Cable A5N2XCH04025 4 2.5 RE Black
N2XCH IEC 60502-1 XLPE CWS FRNC 0.6/1kV Cable A5N2XCH04040 4 4 RE Black
N2XCH IEC 60502-1 XLPE CWS FRNC 0.6/1kV Cable A5N2XCH04060 4 6 RE Black
N2XCH IEC 60502-1 XLPE CWS FRNC 0.6/1kV Cable A5N2XCH0410 4 10 RE Black
N2XCH IEC 60502-1 XLPE CWS FRNC 0.6/1kV Cable A5N2XCH0416 4 16 RE Black
N2XCH IEC 60502-1 XLPE CWS FRNC 0.6/1kV Cable A5N2XCH0425 4 25 RM Black
N2XCH IEC 60502-1 XLPE CWS FRNC 0.6/1kV Cable A5N2XCH0435 4 35 SM Black
N2XCH IEC 60502-1 XLPE CWS FRNC 0.6/1kV Cable A5N2XCH0450 4 50 SMv Black
N2XCH IEC 60502-1 XLPE CWS FRNC 0.6/1kV Cable A5N2XCH0470 4 70 SMv Black
N2XCH IEC 60502-1 XLPE CWS FRNC 0.6/1kV Cable A5N2XCH0495 4 95 SMv Black
N2XCH IEC 60502-1 XLPE CWS FRNC 0.6/1kV Cable A5N2XCH04120 4 120 SMv Black
N2XCH IEC 60502-1 XLPE CWS FRNC 0.6/1kV Cable A5N2XCH04150 4 150 SMv Black
N2XCH IEC 60502-1 XLPE CWS FRNC 0.6/1kV Cable A5N2XCH04185 4 185 SMv Black
N2XCH IEC 60502-1 XLPE CWS FRNC 0.6/1kV Cable A5N2XCH04240 4 240 SMv Black
N2XCH IEC 60502-1 XLPE CWS FRNC 0.6/1kV Cable A5N2XCH05015 5 1.5 RE Black
N2XCH IEC 60502-1 XLPE CWS FRNC 0.6/1kV Cable A5N2XCH07015 7 1.5 RE Black
N2XCH IEC 60502-1 XLPE CWS FRNC 0.6/1kV Cable A5N2XCH07025 7 2.5 RE Black
N2XCH IEC 60502-1 XLPE CWS FRNC 0.6/1kV Cable A5N2XCH07040 7 4 RE Black
N2XCH IEC 60502-1 XLPE CWS FRNC 0.6/1kV Cable A5N2XCH07060 7 6 RE Black
N2XCH IEC 60502-1 XLPE CWS FRNC 0.6/1kV Cable A5N2XCH10025 10 2.5 RE Black
N2XCH IEC 60502-1 XLPE CWS FRNC 0.6/1kV Cable A5N2XCH12015 12 1.5 RE Black
N2XCH IEC 60502-1 XLPE CWS FRNC 0.6/1kV Cable A5N2XCH12025 12 2.5 RE Black
N2XCH IEC 60502-1 XLPE CWS FRNC 0.6/1kV Cable A5N2XCH14015 14 1.5 RE Black
N2XCH IEC 60502-1 XLPE CWS FRNC 0.6/1kV Cable A5N2XCH21025 21 2.5 RE Black
N2XCH IEC 60502-1 XLPE CWS FRNC 0.6/1kV Cable A5N2XCH24015 24 1.5 RE Black
N2XCH IEC 60502-1 XLPE CWS FRNC 0.6/1kV Cable A5N2XCH24025 24 2.5 RE Black
N2XCH IEC 60502-1 XLPE CWS FRNC 0.6/1kV Cable A5N2XCH30015 30 1.5 RE Black
N2XCH IEC 60502-1 XLPE CWS FRNC 0.6/1kV Cable A5N2XCH30025 30 2.5 RE Black