Sub Banner Drum

EXCG, EXeCG and EXeCeG Cables

to EXCG, EXeCG & EXeCeG Cable datasheets

Included in our Medium Voltage range are cables supplied against Belgian references. This includes the EXCG Copper cable with Low Smoke Zero Halogen, flame & fire retardant, sheathing, suitable for internal as well as direct burial power distribution applications. 

Where required, these cables are available with additional longitudinal and radial (transverse) waterblocking properties, where water swellable tapes and/or Al/PET tapes are included in the cable construction. This addition is identified in the cable name.

The EXCG, EXeCG and EXeCeG cables are manufactured in accordance with IEC 60502-2 and Generally to HD 620 10B

EXCG Cable Construction

For ease of reference this is the Belgian cable nomenclature explained. As with many cable naming codes, a copper conductor is assumed unless specifically stated otherwise, in this case listed as the letter A. PDF datasheets for our aluminium variants can be downloaded from the EAXCG, EAXeCG & EAXeCeG page.

E Energy Cable
A in second position Aluminium Conductor
X XLPE insulation
C Concentric copper conductor
e before designation of watertight element (eC) Longitudinal water tightness 
e after designation of watertight element (Ce) Transverse water tightness 
G Polyolefin Outer Sheath for Halogen-free cables with enhanced fire performance
-F2 Fire retardant to EN 60332-3-24 (cat C)

EXCG, EXeCG & EXeCeG cable voltages

These MV cables are available in the following voltages:

Voltage Rating Uo/U (Um) Test Voltage
8.7/15 (17.5) kV 35kV AC 50Hz (5 mins)
12/20 (24)kV 42kV AC 50Hz (5 mins)
18/30 (36)kV 63kV AC 50Hz (5 mins)

Should alternate voltages be required, these can be supplied and a datasheet provided on request.

These Belgian reference cables are of the same construction as the N2XSH Cable (and waterblocked variants) that use the German nomenclature.

EXCG, EXeCG & EXeCeG Specification & Technical Support

Eland Cables' technical team are on-hand to answer specification queries, to ensure the most appropriate cable is identified for your project installation. The technical datasheets linked below also provide key information on cable sizing and electrical properties - as ever, supplemental data is available should it be required. For support, speak to a member of the sales team who will be able to best direct your enquiry.

 

FastQuote Logo

Your tailored quote direct to your inbox

Your basket is currently empty

Go back

More information

Construction Table

  EXCG Cable CS EXCG Cable Execg Cable CS EXeCG Cable Execeg Cable CS EXeCeG Cable
CONDUCTOR

Class 2 Stranded Copper

CONDUCTOR SCREEN

Semi-conductive material (Bonded type)

INSULATION

XLPE (Cross-Linked Polyethylene)

INSULATION SCREEN

Semi-conductive material (Strippabe type)

WATER-BLOCKING

-

Semi Conductive Water Blocking Tape

SCREEN

Copper wires with Open Helix Copper Tape Screen

WATER-BLOCKING 2

-

Non-Conductive Water Blocking Tape

TAPE

-

Aluminium Tape

OUTER SHEATH

LSZH (Low Smoke Zero Halogen)

EXCG, EXeCG and EXeCeG Cables

3 product(s)

YOUR CABLE OPTIONS

Use the FastQuote filters to find the exact cable specifications you need.

Need a bespoke solution? Learn more about customised cables.

Reset

Product name Part No Cores Nominal cross-sectional area (mm²) Sheath colour Length (m)  
EXCG CableB4Q15KV01050150mm²Red
EXCG CableB4Q20KV01050150mm²Red
EXCG CableB4Q30KV01050150mm²Red
EXCG CableB4Q15KV01095195mm²Red
EXCG CableB4Q20KV01095195mm²Red
EXCG CableB4Q30KV01095195mm²Red
EXCG CableB4Q15KV011501150mm²Red
EXCG CableB4Q20KV011501150mm²Red
EXCG CableB4Q30KV011501150mm²Red
EXCG CableB4Q15KV012401240mm²Red
EXCG CableB4Q20KV012401240mm²Red
EXCG CableB4Q30KV012401240mm²Red
EXCG CableB4Q15KV014001400mm²Red
EXCG CableB4Q20KV014001400mm²Red
EXCG CableB4Q30KV014001400mm²Red
EXCG CableB4Q15KV016301630mm²Red
EXCG CableB4Q20KV016301630mm²Red
EXCG CableB4Q30KV016301630mm²Red
EXeCG CableB4R15KV01050150mm²Red
EXeCG CableB4R20KV01050150mm²Red
EXeCG CableB4R30KV01050150mm²Red
EXeCG CableB4R15KV01095195mm²Red
EXeCG CableB4R20KV01095195mm²Red
EXeCG CableB4R30KV01095195mm²Red
EXeCG CableB4R15KV011501150mm²Red
EXeCG CableB4R20KV011501150mm²Red
EXeCG CableB4R30KV011501150mm²Red
EXeCG CableB4R15KV012401240mm²Red
EXeCG CableB4R20KV012401240mm²Red
EXeCG CableB4R30KV012401240mm²Red
EXeCG CableB4R15KV014001400mm²Red
EXeCG CableB4R20KV014001400mm²Red
EXeCG CableB4R30KV014001400mm²Red
EXeCG CableB4R15KV016301630mm²Red
EXeCG CableB4R20KV016301630mm²Red
EXeCG CableB4R30KV016301630mm²Red
EXeCeG CableB4S15KV01050150mm²Red
EXeCeG CableB4S15KV01050150mm²Red
EXeCeG CableB4S30KV01050150mm²Red
EXeCeG CableB4S15KV01095195mm²Red
EXeCeG CableB4S15KV01095195mm²Red
EXeCeG CableB4S30KV01095195mm²Red
EXeCeG CableB4S15KV011501150mm²Red
EXeCeG CableB4S15KV011501150mm²Red
EXeCeG CableB4S30KV011501150mm²Red
EXeCeG CableB4S15KV012401240mm²Red
EXeCeG CableB4S15KV012401240mm²Red
EXeCeG CableB4S30KV012401240mm²Red
EXeCeG CableB4S15KV014001400mm²Red
EXeCeG CableB4S15KV014001400mm²Red
EXeCeG CableB4S30KV014001400mm²Red
EXeCeG CableB4S15KV016301630mm²Red
EXeCeG CableB4S15KV016301630mm²Red
EXeCeG CableB4S30KV016301630mm²Red