N2XFGbY Cable 0.6/1kV

The armoured N2XFGbY cable is for low voltage power distribution and offers a thermoset insulated alternative to the thermoplastic insulated NYFGbY cable, and thus offering an increased maximum operating temperature of 90oC. This DIN VDE 0276-603 compliant 0.6/1kV cable is robust and hardy, with the flat SWA and steel tape armour providing protection from both mechanical stress, accidental damage, and rodent attack. As such the N2XFGbY cable is generally installed externally, including in direct burial applications. Like the thermoplastic alternative, the N2XFGbY cable is UV resistant and flame retardant.

This cable is commonly specified in Continental Europe for connections in power and substations and in industrial environments.

FastQuote Logo

Your tailored quote direct to your inbox

Your basket is currently empty

Go back

More information

Specifying N2XFGbY Cables 

The choice of armoured cable - whether XLPE or PVC insulated, PVC, MDPE or LSZH sheathed, copper or aluminium conductors - can be a challenge. The N2XFGbY with its double layer of armour may suit your installation environment, but in the event you require clarification or further assistance in determining if this is indeed the right cable for your project you can contact our technical team who will be happy to advise.

The N2XFGbY is available on short manufacturing lead times and with low minimum order quantities. 

Construction Table

  N2XFGBY Cable CS N2XFGbY Cable 0.6/1kV
VOLTAGE

0.6/1kV

CONDUCTOR

Class 1 Solid Copper
Class 2 Stranded Copper

INSULATION

XLPE (Cross-Linked Polyethylene)

FILLER

PVC (Polyvinyl Chloride)

ARMOUR

SWA (Galvanised Flat Steel Wire)

ARMOUR 2

Galvanised Steel Tape

OUTER SHEATH

PVC (Polyvinyl Chloride)

N2XFGbY Cable 0.6/1kV

1 product(s)

YOUR CABLE OPTIONS

Use the FastQuote filters to find the exact cable specifications you need.

Need a bespoke solution? Learn more about customised cables.

Reset

Product name Part No Cores Nominal cross-sectional area (mm²) Sheath colour Length (m)  
N2XFGbY Cable 0.6/1kV B2H02010BK 2 10 Black
N2XFGbY Cable 0.6/1kV B2H02016BK 2 16 Black
N2XFGbY Cable 0.6/1kV B2H02025BK 2 25 Black
N2XFGbY Cable 0.6/1kV B2H02035BK 2 35 Black
N2XFGbY Cable 0.6/1kV B2H02050BK 2 50 Black
N2XFGbY Cable 0.6/1kV B2H02070BK 2 70 Black
N2XFGbY Cable 0.6/1kV B2H02095BK 2 95 Black
N2XFGbY Cable 0.6/1kV B2H03010BK 3 10 Black
N2XFGbY Cable 0.6/1kV B2H03016BK 3 16 Black
N2XFGbY Cable 0.6/1kV B2H03025BK 3 25 Black
N2XFGbY Cable 0.6/1kV B2H03035BK 3 35 Black
N2XFGbY Cable 0.6/1kV B2H03050BK 3 50 Black
N2XFGbY Cable 0.6/1kV B2H03070BK 3 70 Black
N2XFGbY Cable 0.6/1kV B2H03095BK 3 95 Black
N2XFGbY Cable 0.6/1kV B2H03120BK 3 120 Black
N2XFGbY Cable 0.6/1kV B2H03150BK 3 150 Black
N2XFGbY Cable 0.6/1kV B2H03185BK 3 185 Black
N2XFGbY Cable 0.6/1kV B2H03240BK 3 240 Black
N2XFGbY Cable 0.6/1kV B2H0316/10BK 3+ 16/10 Black
N2XFGbY Cable 0.6/1kV B2H03025/16BK 3+ 25/16 Black
N2XFGbY Cable 0.6/1kV B2H03035/16BK 3+ 35/16 Black
N2XFGbY Cable 0.6/1kV B2H03050/25BK 3+ 50/25 Black
N2XFGbY Cable 0.6/1kV B2H03070/35BK 3+ 70/35 Black
N2XFGbY Cable 0.6/1kV B2H03095/50BK 3+ 95/50 Black
N2XFGbY Cable 0.6/1kV B2H03120/70BK 3+ 120/70 Black
N2XFGbY Cable 0.6/1kV B2H03150/70BK 3+ 150/70 Black
N2XFGbY Cable 0.6/1kV B2H03185/95BK 3+ 185/95 Black
N2XFGbY Cable 0.6/1kV B2H03240/120BK 3+ 240/120 Black
N2XFGbY Cable 0.6/1kV B2H04010BK 4 10 Black
N2XFGbY Cable 0.6/1kV B2H04016BK 4 16 Black
N2XFGbY Cable 0.6/1kV B2H04025BK 4 25 Black
N2XFGbY Cable 0.6/1kV B2H04035BK 4 35 Black
N2XFGbY Cable 0.6/1kV B2H04050BK 4 50 Black
N2XFGbY Cable 0.6/1kV B2H04070BK 4 70 Black
N2XFGbY Cable 0.6/1kV B2H04095BK 4 95 Black
N2XFGbY Cable 0.6/1kV B2H04120BK 4 120 Black
N2XFGbY Cable 0.6/1kV B2H04150BK 4 150 Black
N2XFGbY Cable 0.6/1kV B2H04185BK 4 185 Black
N2XFGbY Cable 0.6/1kV B2H04240BK 4 240 Black
N2XFGbY Cable 0.6/1kV B2H05010BK 5 10 Black
N2XFGbY Cable 0.6/1kV B2H05016BK 5 16 Black
N2XFGbY Cable 0.6/1kV B2H05025BK 5 25 Black
N2XFGbY Cable 0.6/1kV B2H05035BK 5 35 Black
N2XFGbY Cable 0.6/1kV B2H05050BK 5 50 Black