Eland Cables Cable Information (1)

Concentric and Split Concentric Cables

Eland Cables supplies a comprehensive range of concentric and split concentric cables manufactured in accordance with standard BS7870. These aluminium and copper cables are UK Power Network (UKPN) approved and are devised for use by Distribution Network Operators (DNOs) to provide the final connection to residential properties. Additional functionality includes use for sub-main distribution and within high-rise buildings and street lighting systems.

The choice between Concentric and Split Concentric cable is determined by the supply type: TN-C-S supply for Concentric and TN-S supply for Split Concentric. These are LSZH cables (low smoke zero halogen) with the outersheath suitable for installations requiring a reduction to the risk to human life or sensitive equipment in the event of fire.

Concentric Cable Specification

These cables are used for power supplies with Protective Multiple Earthing (PME) systems, where a combined Protective Earth (PE) and Neutral (N) - together known as the PEN - connects the combined neutral-and-earth to real earth at multiple locations to reduce the risk of electric shock in the event of a broken PEN. They are manufactured in accordance with BS7870-3.10 (PVC insulation and sheathing), BS7870-3.11 (XLPE insulation / PVC sheathing) and BS7870-3.12 (XLPE insulation / LSZH sheathing)

Split Concentric Cable Specification

These cables are used when the power supply has separate PE & N conductors and are only combined as PEN near the power source. The Protective Earth and Neutral are not connected after the building entry point. They are manufactured in accordance with BS7870-3.20 (PVC insulation and sheathing), BS7870-3.21 (XLPE insulation / PVC sheathing) and BS7870-3.22 (XLPE insulation / LSZH sheathing).

Concentric & Split Concentric Cable Datasheets

The technical datasheets provided cover the dimensional data and electrical characteristics required to support sizing and specification. The electrical characteristics are in line with BS7671 Wiring Regulations and EN 60228 for conductor resistance.

Please contact us for technical support with the right cable selection for your power distribution projects and to discuss your maintenance or project specific requirements. We provide tailored solutions for this cable range which include storage, cutting to length, and same-day collection or next-day delivery as standard.

FastQuote Logo

Your tailored quote direct to your inbox

Your basket is currently empty

Go back

Construction Table

  BS7870 Aluminium Concentric PVC Cable CS Aluminium Concentric BS 7870 PVC Cable BS7870 Copper Split Concentric PVC Cable CS Copper LSZH Split Concentric BS7870 BS7870 Aluminium Concentric LSZH Cable CS Aluminium Concentric BS 7870 LSZH Cable BS7870 Aluminium Split Concentric PVC Cable CS Aluminium Split Concentric BS 7870 PVC Cable BS7870 Aluminium Split Concentric LSZH Cable CS Aluminium Split Concentric BS 7870 LSZH Cable BS7870 Copper Concentric Cable CS Copper Concentric BS 7870 PVC Cable BS7870 Copper Split Concentric PVC Cable CS Copper Split Concentric BS 7870 PVC Cable
VOLTAGE

0.6/1kV

CONDUCTOR

Class 1 Solid Aluminium

Class 2 stranded Copper

Class 1 Solid Aluminium

Class 2 Stranded Copper

INSULATION

XLPE (Cross-Linked Polyethylene)

XLPE (Cross-linked Polyethylene)

XLPE (Cross-Linked Polyethylene)

CONCENTRIC CONDUCTOR

Single Layer of Plain Copper Wires

-

Single Layer of Plain Copper Wires

-

Single Layer of Plain Copper Wires

-

NEUTRAL CONDUCTOR

-

Plain Copper Wires covered by a Polymeric Compound

-

Plain Copper Wires covered by a Polymeric Compound

-

Plain Copper Wires covered by a Polymeric Compound

EARTH CONTINUITY CONDUCTOR

-

Plain Copper wires

-

Plain Copper Wires

-

Plain Copper Wires

STRING SEPARATOR

-

Non-Hygroscopic

-

Non-Hygroscopic

-

Non-Hygroscopic

OUTER SHEATH

PVC (Polyvinyl Chloride)

LSZH (Low Smoke Zero Halogen)

PVC (Polyvinyl Chloride)

LSZH (Low Smoke Zero Halogen)

PVC (Polyvinyl Chloride)

YOUR CABLE OPTIONS

Use the FastQuote filters to find the exact cable specifications you need.

Need a bespoke solution? Learn more about customised cables.

Reset

Product name Part No Cores Nominal cross-sectional area (mm²) Sheath colour Length (m)  
Aluminium Concentric BS 7870 PVC CableA1S/311/125125mm²Black
Aluminium Concentric BS 7870 PVC CableA1S/311/135135mm²Black
Aluminium Concentric BS 7870 PVC CableA1S/311/325325mm²Black
Aluminium Concentric BS 7870 PVC CableA1S/311/335335mm²Black
Copper LSZH Split Concentric BS7870A1S/321C/1040L14mm²Black
Copper LSZH Split Concentric BS7870A1S/321C/116L116mm²Black
Copper LSZH Split Concentric BS7870A1S/321C/125L125mm²Black
Copper LSZH Split Concentric BS7870A1S/321C/135L135mm²Black
Aluminium Concentric BS 7870 LSZH CableA1S/312/125125mm²Orange
Aluminium Concentric BS 7870 LSZH CableA1S/312/135135mm²Orange
Aluminium Concentric BS 7870 LSZH CableA1S/312/325325mm²Orange
Aluminium Concentric BS 7870 LSZH CableA1S/312/335335mm²Orange
Aluminium Split Concentric BS 7870 PVC CableA1S/321/125125mm²Black
Aluminium Split Concentric BS 7870 PVC CableA1S/321/135135mm²Black
Aluminium Split Concentric BS 7870 PVC CableA1S/321/325325mm²Black
Aluminium Split Concentric BS 7870 PVC CableA1S/321/335335mm²Black
Aluminium Split Concentric BS 7870 LSZH CableA1S/322/125125mm²Orange
Aluminium Split Concentric BS 7870 LSZH CableA1S/322/135135mm²Orange
Aluminium Split Concentric BS 7870 LSZH CableA1S/322/325325mm²Orange
Aluminium Split Concentric BS 7870 LSZH CableA1S/322/335335mm²Orange
Copper Concentric BS 7870 PVC CableA1S/311C/104014mm²Black
Copper Concentric BS 7870 PVC CableA1S/311C/116116mm²Black
Copper Concentric BS 7870 PVC CableA1S/311C/125125mm²Black
Copper Split Concentric BS 7870 PVC CableA1S/321C/104014mm²Black
Copper Split Concentric BS 7870 PVC CableA1S/321C/116116mm²Black
Copper Split Concentric BS 7870 PVC CableA1S/321C/125125mm²Black
Copper Split Concentric BS 7870 PVC CableA1S/321C/335335mm²Black