Eland Cables supplies a wide range of products to the oil, gas and petrochemical industries where safety and performance are critical. The company supplies cost-effective, high quality solutions that are fully compliant with national and international standards – ensuring the long-term reliable operation of platforms and plants.

Whether supplying cabling solutions for Mobile Offshore Drilling Units (MODUs), Floating Production Storage and Offloading units (FPSOs), platforms or processing plants, customers can choose from a wide range of solutions capable of withstanding the toughest environmental conditions. Its portfolio of cables offers excellent resistance to oils, abrasion, petrochemical fluids and moisture, while the latest Firecel range is capable of providing fire resistance to protect a circuit’s integrity for up to 30 minutes. Supplied alongside low smoke, zero halogen cables, the company’s range of cables helps contribute to ensuring the highest levels of safety in these potentially hazardous areas.

The company’s range of solutions is constantly expanding – including steel wired armoured cable; power cables in a variety of materials and voltages from 11 to 44kV; as well as a selection of multicore, screened data cables to meet the most stringent defence standards.

Firecel SR 114E Enhanced Fire Cable PH120 Firecel SR 114E Enhanced Fire Cable PH120 Toggle

Eland Product Group: A6F

Application: Firecel SR 114E Fire Performance Cable is intended for use in fire detection and fire alarm systems, and emergency lighting circuits. Firecel 114E Enhanced cable is recommended for situations where fire cables may need to remain operating correctly for a longer period than is expected of a standard fire cable. Firecel PH120 is capable of maintaining circuitry for up to 120 minutes after the detection of fire. This added level of security is invaluable in buildings without sprinkler systems, which have a longer evacuation process due to the size, complexity or purpose of the building, or any building that has been assessed as requiring enhanced fire protection.

Full Product Specification

BS5308 Instrumentation Cable Part 2 Type 1 BS5308 Instrumentation Cable Part 2 Type 1 Toggle

Eland Product Group: I

Application: BS5308 cables are designed to carry communication and control signals in a variety of installation types including the petrochemical industry. The signals can be of analogue, data or voice type and from a variety of transducers such as pressure, proximity or microphone. BS 5308 cables are designed to form part of an intrinsically safe system and the technical information required to determine their suitability for this application is contained within the datasheet. Part 2 Type 1 cables are generally designed for indoor use and in environments where mechanical protection is not required. Being BS 5308 Part 2 the insulation material is PVC. The PVC sheathing material has an OI >30% and HCL <15% and the LSZH material is of type LTS3. Individually and collectively screened pairs are available within the range where further signal security is required.

Full Product Specification

Multi-Core Data Cables to Def Stan 61/12 Part 4 Multi-Core Data Cables to Def Stan 61/12 Part 4 Toggle

Eland Product Group: A2D

Application: These Multi-Core flexible cables are designed for high density wiring between components and within instruments and electronic equipment. They are extensively used in aircraft, process control systems, computers, data processors, military vehicles and military equipment.

Full Product Specification

Multi-Core Data Cables to Def Stan 61/12 Part 5 Multi-Core Data Cables to Def Stan 61/12 Part 5 Toggle

Eland Product Group: A2D

Application: These multicore flexible cables are designed for high density wiring between components and within instruments and electronic equipment. They are extensively used in aircraft, process control systems, computers, data processors, military vehicles and military equipment.

Full Product Specification

BS5308 Instrumentation Cable Part 1 Type 2 BS5308 Instrumentation Cable Part 1 Type 2 Toggle

Eland Product Group: I

Application: BS5308 cables are designed to carry communication and control signals in a variety of installation types including those found in the petrochemical industry. The signals can be of analogue, data or voice type and from a variety of transducers such as pressure, proximity or microphone. BS 5308 cables are designed to form part of an intrinsically safe system and the technical information required to determine their suitability for this application is contained within the datasheet. Part 1 Type 2 cables are designed where a greater degree of mechanical protection is required namely outdoor / exposed or direct burial at suitable depth. Being BS 5308 Part 1 the insulation material is either PE or XLPE. The PVC sheathing material has an OI >30% and HCL <15% and the LSZH material is of type LTS3. Collectively and individually screened pairs are available within the range where further signal security is required.

Full Product Specification

BS5308 Instrumentation Cable Part 1 Type 1 BS5308 Instrumentation Cable Part 1 Type 1 Toggle

Eland Product Group: I

Application: BS5308 cables are designed to carry communication and control signals in a variety of installation types including those found in the petrochemical industry. The signals can be of analogue, data or voice type and from a variety of transducers such as pressure, proximity or microphone. BS 5308 cables are designed to form part of an intrinsically safe system and the technical information required to determine their suitability for this application is contained within the datasheet. Part 1 Type 1 cables are generally designed for indoor use and in environments where mechanical protection is not required. Being BS 5308 Part 1 the insulation material is either PE or XLPE. The PVC sheathing material has an OI >30% and HCL <15% and the LSZH material is of type LTS3. Collectively and individually screened pairs are available within the range where further signal security is required.

Full Product Specification

11kV XLPE PVC Cable 11kV XLPE PVC Cable Toggle

Eland Product Group: A9M

Application: 11kV XLPE power cables for power networks, underground, outdoors and in cable ducting. Our 11kV cables are certified to two British Standards - BS6622 and BS EN/IEC 60228. Sheathed in a durable PVC sheathing, they form part of our extensive medium voltage cable range.

Full Product Specification

11kV XLPE LSZH Cable BS7835 11kV XLPE LSZH Cable BS7835 Toggle

Eland Product Group: A9M

Application: 11kV XLPE LSZH power cables for power networks, underground, outdoors and in cable ducting. Its LSZH sheath makes it suitable for installations where fire, smoke emissions and toxic fumes create a potential threat. Our 11kV XLPE LSZH Cable is certified to BS7835 and IEC 60754-1.

Full Product Specification

33kV XLPE Cable 33kV XLPE Cable Toggle

Eland Product Group: A9M

Application: 33kV XLPE power cables for power networks, underground, outdoors and in cable ducting. Certified to British Standard 6622, our 33kV cable is part of our wider medium voltage cable range.

Full Product Specification

BS5308 Instrumentation Cable Part 2 Type 2 BS5308 Instrumentation Cable Part 2 Type 2 Toggle

Eland Product Group: I

Application: BS5308 cables are designed to carry communication and control signals in a variety of installation types including the petrochemical industry. The signals can be of analogue, data or voice type and from a variety of transducers such as pressure, proximity or microphone. BS 5308 cables are designed to form part of an intrinsically safe system and the technical information required to determine their suitability for this application is contained within the datasheet. Part 2 Type 2 cables are designed where a greater degree of mechanical protection is required namely outdoor / exposed or direct burial at suitable depth. Being BS 5308 Part 2 the insulation material is PVC, whilst the PVC sheathing material has an OI >30% and HCL <15% and the LSZH material is of type LTS3. Individually and collectively screened pairs are available within the range where further signal security is required.

Full Product Specification